Atlas Log Multi-use Ultra Low Temperature Data Logger

Atlas Log Multi-use Ultra Low Temperature Data Logger

Suitable for ultra-low/high temperature logging

Single use/Multi use, parameters configurable

Multiple temperature ranges: -60℃~+200℃/-90℃~+200℃/-196℃~+200℃

Up to 6 alarm points

Mark and pause function

Temporary reports

Pluggable external probe

Flexible ultra thin cable

7.jpgIntroduction



Atlas Log Series are single use/multi use temperature data loggers for ultra-low or ultra-high temperature monitoring. They come with a pluggable external probe with optional temperature ranges of -60℃~+200℃/-90℃~+200℃/-196℃~+200℃, to better meet user needs. Besides, they are configurable, battery replaceable, and have an LCD screen for intuitive display. After completing the trip, an encrypted report can be automatically generated.


These ultra-low temperature data loggers are designed for cold chain logistics, storage and transportation, especially for dry ice, liquid nitrogen and other ultra-low/ultra-high temperature applications.


Features


Parameters configurable 

Parameters can be freely configured through the configuration software.


Replaceable battery

The battery can be replaced.


Alarm points and markers

Up to 6 alarm points can be set, and up to 9 markings can be made.


Password protection

Password can be set to prevent others from operating the equipment without authorization.


High precision 

The external probe can measure temperature as low as -196℃ with high accuracy.


Intuitive LCD display

LCD displays: normal, alarm, max/min/average temperature value, running status, and battery level, etc.


Temporary Report Available

Temporary mode allows the device to continue working after the user exports and reads a temporary report. Current data information can be read via configuration software.


Automatic PDF/CSV Reports

It can automatically generate PDF/CSV/PDF+CSV reports with graphs and tables without additional software.


LCD alarm indication  and optional buzzer alarm available

Once the temperature out of the presetting alarm range, the alarm symbol(x) will be displayed on the LCD screen. Buzzer alarm is customizable.

 

Temperature units switchable

Celsius (℃) and Fahrenheit (℉) can be freely switched.

 

Large memory capacity

Max. 35000 readings for only PDF reports; Max. 20000 readings for PDF&CSV reports. 



Multiple probe length and insulation options for the external probes

The external pluggable cable is normally 2m long and other cable lengths are customizable; cable insulation materials are also customizable, including PVC, Teflon, Silicone and flexible ultra thin cable, etc.

Flexible ultra thin cable is suitable for refrigerator door and other application environment with high sealing requirements. Besides, users can also choose sharp or blunt sensor head as required.



Specification


Model

Atlas Log-60

Atlas Log-90

Atlas Log-200

Temperature Range

-60℃~+200℃

-90℃~+200℃

-196℃~+200℃

Temperature Accuracy

±0.5℃ F.S.

±0.5℃(-90℃~+70℃); ±1.0℃ (others)

Temperature Resolution

0.1℃

Start Delay

0 minute-24 hours

Logging Interval

1 minute-24 hours

Alarms and Marks

Max. 6 alarm points and 9 marks

Memory Capacity

Max. 35,000 readings

Report Format

PDF, CSV, PDF&CSV

Recording Days

Max. 90 days

Battery

3.0V CR2450 button cell, replaceable

Alarm Type

LCD display, optional buzzer alarm (about 60dB at 3m)

Certifications

CE, RoHS, EN12830

Dimensions

96mm*44mm*15mm (main device)


Applications


Atlas Log Series Ultra Low Temperature Data Logger can be widely used to monitor and record temperature in cold chain logistics, storage and transportation of biopharmaceuticals, life sciences, biological samples, and diagnostic reagents in a low-temperature environment, etc.



tools.jpg

Freshliance Tools


Freshliance Tools is a desktop software for users to use Freshliance USB data loggers. It consists of three pages: Summary, Graph and History. On the Summary page, the software will first automatically identify ID, model, recording type, sensor type, battery level, status and other information of the device plugged in. And then users can configure the data logger as needed, including start mode, start delay, time zone, time format, logging interval, report format, PDF/software password, high and low alarm, etc. During or after data recording, user can also check statistical information of the device after plugging it in. Besides, the graph page provides a simple X–Y plot of time versus temperature/humidity which can be save as PNG format file, a list and a summary of all data recorded, as well as an option to export the report in PDF, CSV, TXT format; and the history page provides a list of all the devices whose report was read by this software.


The software is designed for Fresh Tag 10T/TH, Thermis Log 10T/TH, Tagplus-T/TH, Atlas Log-30/60/90/200/IUT, Rugged data logger, Keeper 1/IUT, COEUS-UEX.


Online message

* Parts are required. Please fill and then submit.


E-mail is required.
Country/Region is required.
Message content is required.